Gas mask-self-rescuer PHOENIX-2TM

 

The portable gas mask self-rescuer PHOENIX-2TM has sorbent of 90 mm diameter and the increased height of sorbent layer therefore the charges volume is increased by 1,5 times in comparison with base model PHOENIXTM. That's why protective action for poisoning substances of groups A, B, Е, K is increased up to 60 minutes

The gas mask self-rescuer PHOENIX-2TM is intended for protection of respiratory apparatus during evacuation of people from zones of contamination caused by accidents on harmful chemical manufactures or other extreme situations demanding time to evacuate up to 60 minutes.

Basic characteristics of PHOENIX-2TM are presented in таb.4.

Тable 4

Group

Testing substance

Concentration of the test-substance, mg/m3

Period of protective action, min., not less

Class of protection in accordance with GOST Р 22.9.09-2005

Ð

 

Cyclohexane

2500

60

N/A

Benzol

2500

60

N/A

ÐÐ¥

 

Acrolein

100

60

3

Ð’

Chlorine

300

60

3

 

Sulphuretted hydrogen

1000

60

3

 

 

Hydrogen cyanide

300

60

3

Е

Sulfur dioxide

1000

60

3

 

 

Hydrogen chloride

400

60

3

К

Ammonia

400

60

1

Weight in package, g, no more

230

Volume in package, cm3, no more

570

In July 2007 export model of the self-rescuer - PHOENIX-T2TM - was certified in the EU and received European Certificate for personal safety equipment (you can see it in the "CERTIFICATES" directory.