Russian (CIS)English (United Kingdom)

Such a design of filtering-absorbing system allows having wide enough surface of the anti-aerosol filter in working conditions and the minimal space-consuming package at storage.

The product is put in vacuum package that allows to reduce its dimensions on the one hand and to prevent contacts with atmospheric air and moisture at storage on another.

 

Basic characteristics of the PHOENIXTM protective hood.

 

Resistance of a filtering-absorbing system to a constant air stream on a breath at the volumetric rate of 30 dm3 per minute - no more than 284 Pа.

Table 1.

 

Protective properties of the PHOENIXTM protective hood on the testing substances

 

Testing substance

Operating concentration

Overshoot concentration

Period of protective action, minutes, not less

 

mg/l

ррм

ррм

Cyclohexane (А)

3,0

850

10

30

Chlorine (В)

0,3

100

0,5

30

Sulphuretted hydrogen (В)

0,70

500

10

30

Hydrocyanic acid (В)

0,05

45

4,5

30

Sulfur dioxide (Е)

0,30

110

5

30

Ammonia (К)

0,50

710

25

30

Acrolein (АХ)

0,24

100

0,5

30

Hydrogen chloride (Е)

0,4

250

5

30